refactor: rename ScadaLink → ZB.MOM.WW.ScadaBridge (code + projects + namespaces)

Solution + 23 src projects + 26 test projects renamed; folders, csproj,
namespaces, and ScadaLinkDbContext/ScadaBridgeDbContext class updated.
ActorSystem "scadalink" → "scadabridge", Akka seed-node URLs migrated.
SQL roles/logins, LDAP domains, CLI command name, and CLI config dir
(~/.scadalink → ~/.scadabridge) also renamed.

Build green; 5 Host.Tests fail awaiting SQL login rename in next commit.
Pre-existing StaleTagMonitor timing flakes unchanged.

Rename script committed at tools/rename-to-scadabridge.sh.
This commit is contained in:
Joseph Doherty
2026-05-28 09:37:45 -04:00
parent 6d87ee3c3b
commit 7b0b9c7365
1531 changed files with 11180 additions and 11054 deletions
@@ -0,0 +1,23 @@
namespace ZB.MOM.WW.ScadaBridge.DataConnectionLayer;
/// <summary>
/// Configuration options for the Data Connection Layer.
/// </summary>
public class DataConnectionOptions
{
/// <summary>Fixed interval between reconnect attempts after disconnect.</summary>
public TimeSpan ReconnectInterval { get; set; } = TimeSpan.FromSeconds(5);
/// <summary>Interval for retrying failed tag path resolution.</summary>
public TimeSpan TagResolutionRetryInterval { get; set; } = TimeSpan.FromSeconds(10);
/// <summary>Timeout for synchronous write operations to devices.</summary>
public TimeSpan WriteTimeout { get; set; } = TimeSpan.FromSeconds(30);
/// <summary>
/// Minimum time a connection must stay up before it is considered stable.
/// If a connection drops before this threshold, it counts as an unstable
/// disconnect toward the failover retry count (DataConnectionLayer-009).
/// </summary>
public TimeSpan StableConnectionThreshold { get; set; } = TimeSpan.FromSeconds(60);
}