fix(options): canonicalize Communication/DataConnection config sections to ScadaBridge:*; drop the duplicate Host bindings that were masking the drift (plan R2-08 T9, arch-review 08r2 NF8)

This commit is contained in:
Joseph Doherty
2026-07-13 10:58:28 -04:00
parent 973e59de84
commit 7943d73e71
9 changed files with 119 additions and 42 deletions
@@ -4,7 +4,7 @@ namespace ZB.MOM.WW.ScadaBridge.DataConnectionLayer;
/// <summary>
/// Validates <see cref="DataConnectionOptions"/> at startup (ValidateOnStart) so a
/// malformed "DataConnectionLayer" appsettings section fails fast at boot with a
/// malformed "ScadaBridge:DataConnection" appsettings section fails fast at boot with a
/// key-naming message instead of surfacing later at runtime. The intervals drive
/// the reconnect/tag-resolution timers and the seed-read retry loop; a
/// zero/negative duration (or a non-positive <c>SeedReadMaxAttempts</c>) would
@@ -16,24 +16,24 @@ public sealed class DataConnectionOptionsValidator : OptionsValidatorBase<DataCo
protected override void Validate(ValidationBuilder builder, DataConnectionOptions options)
{
builder.RequireThat(options.ReconnectInterval > TimeSpan.Zero,
$"DataConnectionLayer:ReconnectInterval must be a positive duration (was {options.ReconnectInterval}).");
$"ScadaBridge:DataConnection:ReconnectInterval must be a positive duration (was {options.ReconnectInterval}).");
builder.RequireThat(options.TagResolutionRetryInterval > TimeSpan.Zero,
$"DataConnectionLayer:TagResolutionRetryInterval must be a positive duration (was {options.TagResolutionRetryInterval}).");
$"ScadaBridge:DataConnection:TagResolutionRetryInterval must be a positive duration (was {options.TagResolutionRetryInterval}).");
builder.RequireThat(options.WriteTimeout > TimeSpan.Zero,
$"DataConnectionLayer:WriteTimeout must be a positive duration (was {options.WriteTimeout}).");
$"ScadaBridge:DataConnection:WriteTimeout must be a positive duration (was {options.WriteTimeout}).");
builder.RequireThat(options.SeedReadTimeout > TimeSpan.Zero,
$"DataConnectionLayer:SeedReadTimeout must be a positive duration (was {options.SeedReadTimeout}).");
$"ScadaBridge:DataConnection:SeedReadTimeout must be a positive duration (was {options.SeedReadTimeout}).");
builder.RequireThat(options.StableConnectionThreshold > TimeSpan.Zero,
$"DataConnectionLayer:StableConnectionThreshold must be a positive duration (was {options.StableConnectionThreshold}).");
$"ScadaBridge:DataConnection:StableConnectionThreshold must be a positive duration (was {options.StableConnectionThreshold}).");
builder.RequireThat(options.SeedReadRetryDelay > TimeSpan.Zero,
$"DataConnectionLayer:SeedReadRetryDelay must be a positive duration (was {options.SeedReadRetryDelay}).");
$"ScadaBridge:DataConnection:SeedReadRetryDelay must be a positive duration (was {options.SeedReadRetryDelay}).");
builder.RequireThat(options.SeedReadMaxAttempts > 0,
$"DataConnectionLayer:SeedReadMaxAttempts must be positive (was {options.SeedReadMaxAttempts}).");