feat(flow-debugger): carry site-side trace truncation on the route reply (ScadaBridge#54)
ScriptCallResult and RouteToCallResponse gain trailing Truncated/LogsTruncated, filled from the site FlowTraceCollector after Complete(); RouteToCallResponseDto fields 8/9 carry them (sitecommand regen). FlowDebugRunner ORs them into FlowDebugRunResult on the script entry, and on the method entry through a new optional truncation sink on RouteHelper.WithTraceSink (carried through every With* clone). Previously a site run whose collector dropped rows came back as a silently short list. Older sites send false. Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
This commit is contained in:
@@ -4,10 +4,14 @@ namespace ZB.MOM.WW.ScadaBridge.Commons.Messages.ScriptExecution;
|
||||
|
||||
/// <param name="ExecutionId">Flow Debugger — the run's own <c>ExecutionId</c> (design 2026-09-05 §5.4). Additive; null from callers that predate the field.</param>
|
||||
/// <param name="TraceEvents">Flow Debugger — the run's <c>ScriptTrace</c> audit events in emission order when traced (design 2026-09-05 §5.4); null otherwise.</param>
|
||||
/// <param name="Truncated">Flow Debugger (Gitea #54) — the site's inline trace collector dropped a step row (event cap or byte budget), so <see cref="TraceEvents"/> is short. The audit rows are complete; Replay shows everything. Additive; false when untraced.</param>
|
||||
/// <param name="LogsTruncated">Flow Debugger (Gitea #54) — the site's collector dropped low-priority log-line rows to keep room for the step rows. Additive; false when untraced.</param>
|
||||
public record ScriptCallResult(
|
||||
string CorrelationId,
|
||||
bool Success,
|
||||
object? ReturnValue,
|
||||
string? ErrorMessage,
|
||||
Guid? ExecutionId = null,
|
||||
IReadOnlyList<AuditEvent>? TraceEvents = null);
|
||||
IReadOnlyList<AuditEvent>? TraceEvents = null,
|
||||
bool Truncated = false,
|
||||
bool LogsTruncated = false);
|
||||
|
||||
Reference in New Issue