docs(tests): fix CommentChecker findings across tests/ — 13,392 → 0 (repo-wide scan clean)
Comment/XML-doc changes only: - add summaries to ~10k test methods, fixtures, fakes and helpers (+ <param> on theories, <returns> on async Task methods, <inheritdoc/> on interface implementations the checker can resolve) - strip ~2.6k project-tracking references (WP*, P*-*, row-NN, Task N, #NN, Component-0NN) from comments, keeping the explanatory text; reword false positives in comments only - real docs on fakes implementing BCL/library interfaces (IDisposable, ILogger, IOptionsMonitor, IAsyncLifetime) - reword the last 5 src/ false positives (CWE-1236, failures-1, year-0001, M365) Only non-comment edits: four one-line nested classes split across lines so members can carry docs. Build 0 errors / 0 warnings.
This commit is contained in:
+14
-2
@@ -4,7 +4,7 @@ using ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Adapters;
|
||||
namespace ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Tests.Adapters;
|
||||
|
||||
/// <summary>
|
||||
/// Gitea #14: stored bindings hard-code a namespace <i>index</i>, which is only
|
||||
/// Stored bindings hard-code a namespace <i>index</i>, which is only
|
||||
/// meaningful against one server's namespace table. These tests pin the durable
|
||||
/// <c>nsu=<uri></c> form and the back-compat of the existing <c>ns=</c> form.
|
||||
/// </summary>
|
||||
@@ -32,6 +32,7 @@ public class OpcUaNodeReferenceTests
|
||||
return t;
|
||||
}
|
||||
|
||||
/// <summary>Verifies that the legacy namespace index form still resolves.</summary>
|
||||
[Fact]
|
||||
public void Resolve_IndexForm_StillWorks()
|
||||
{
|
||||
@@ -42,6 +43,7 @@ public class OpcUaNodeReferenceTests
|
||||
Assert.Equal("pymodbus/plc/HR200", nodeId.Identifier);
|
||||
}
|
||||
|
||||
/// <summary>Verifies that the namespace URI form resolves to the server's live namespace index.</summary>
|
||||
[Fact]
|
||||
public void Resolve_UriForm_MapsToLiveIndex()
|
||||
{
|
||||
@@ -51,6 +53,7 @@ public class OpcUaNodeReferenceTests
|
||||
Assert.Equal("pymodbus/plc/HR200", nodeId.Identifier);
|
||||
}
|
||||
|
||||
/// <summary>Verifies that the namespace URI form tracks the index across servers with different namespace tables.</summary>
|
||||
[Fact]
|
||||
public void Resolve_UriForm_TracksIndexAcrossServers()
|
||||
{
|
||||
@@ -68,10 +71,11 @@ public class OpcUaNodeReferenceTests
|
||||
Assert.Equal(3, moved.NamespaceIndex); // followed the URI, not the index
|
||||
}
|
||||
|
||||
/// <summary>Verifies that the index form silently binds to a different namespace after a server upgrade.</summary>
|
||||
[Fact]
|
||||
public void Resolve_IndexForm_SilentlyBindsToTheWrongNamespace_AcrossServerUpgrade()
|
||||
{
|
||||
// This is the #14 hazard, pinned as a characterisation test rather than a wish:
|
||||
// This is the namespace-index hazard, pinned as a characterisation test rather than a wish:
|
||||
// v2's sole custom namespace and v3's raw namespace BOTH sit at index 2, so a
|
||||
// v2-era ns=2 binding resolves happily against v3 while meaning something else
|
||||
// entirely. Nothing in the index form can detect that — which is the whole
|
||||
@@ -91,6 +95,7 @@ public class OpcUaNodeReferenceTests
|
||||
Assert.Contains("does not publish", ex.Message);
|
||||
}
|
||||
|
||||
/// <summary>Verifies that resolving an unknown namespace URI throws.</summary>
|
||||
[Fact]
|
||||
public void Resolve_UnknownNamespaceUri_Throws()
|
||||
{
|
||||
@@ -100,6 +105,7 @@ public class OpcUaNodeReferenceTests
|
||||
Assert.Contains("NamespaceArray", ex.Message);
|
||||
}
|
||||
|
||||
/// <summary>Verifies that resolving a reference to another server throws.</summary>
|
||||
[Fact]
|
||||
public void Resolve_ForeignServerReference_Throws()
|
||||
{
|
||||
@@ -109,6 +115,8 @@ public class OpcUaNodeReferenceTests
|
||||
Assert.Contains("another server", ex.Message);
|
||||
}
|
||||
|
||||
/// <summary>Verifies that an unparseable reference throws.</summary>
|
||||
/// <param name="reference">The malformed node reference.</param>
|
||||
[Theory]
|
||||
[InlineData("")]
|
||||
[InlineData(" ;;; not a node id")]
|
||||
@@ -117,6 +125,7 @@ public class OpcUaNodeReferenceTests
|
||||
Assert.ThrowsAny<ArgumentException>(() => OpcUaNodeReference.Resolve(reference, V3Table()));
|
||||
}
|
||||
|
||||
/// <summary>Verifies that a server namespace is converted to the durable URI form.</summary>
|
||||
[Fact]
|
||||
public void ToDurable_ServerNamespace_EmitsUriForm()
|
||||
{
|
||||
@@ -127,6 +136,7 @@ public class OpcUaNodeReferenceTests
|
||||
Assert.Equal($"nsu={RawUri};s=pymodbus/plc/HR200", durable);
|
||||
}
|
||||
|
||||
/// <summary>Verifies that the standard namespace stays in the short form.</summary>
|
||||
[Fact]
|
||||
public void ToDurable_StandardNamespace_StaysShort()
|
||||
{
|
||||
@@ -136,6 +146,7 @@ public class OpcUaNodeReferenceTests
|
||||
Assert.Equal("i=85", durable);
|
||||
}
|
||||
|
||||
/// <summary>Verifies that a durable reference round-trips through resolve.</summary>
|
||||
[Fact]
|
||||
public void ToDurable_RoundTripsThroughResolve()
|
||||
{
|
||||
@@ -151,6 +162,7 @@ public class OpcUaNodeReferenceTests
|
||||
Assert.Equal("Area/Line/Equip/Speed", resolved.Identifier);
|
||||
}
|
||||
|
||||
/// <summary>Verifies that a URI missing from the namespace table falls back instead of throwing.</summary>
|
||||
[Fact]
|
||||
public void ToDurable_UriNotInTable_FallsBackRatherThanThrowing()
|
||||
{
|
||||
|
||||
Reference in New Issue