feat(host): build the process logger through the shared AddZbSerilog bootstrap (#94)
Switch ScadaBridge from its own LoggerConfigurationFactory to AddZbSerilog (ZB.MOM.WW.Telemetry(.Serilog) 0.1.0 -> 0.2.0) using the two 0.2.0 hooks: - MinimumLevelGovernor: ScadaBridge:Logging:MinimumLevel, applied after ReadFrom.Configuration so it outranks Serilog:MinimumLevel (never null, so the floor never defers to the Serilog key; Override:* namespace entries still apply; the one-shot conflict / unparseable-value warnings are unchanged). - ConfigureLogger: the standby active-node exclusion filter (register row 71), the configured node identity (the shared bootstrap stamps NodeHostname from the machine name and skips empty values; an overwriting enricher keeps the configured ScadaBridge:Node values verbatim), Enrich.FromLogContext and the ExecutionLogCaptureSink. ScadaBridgeLogging runs AddZbSerilog on a small pre-host builder and Program installs the result as the static Log.Logger; both web hosts keep UseSerilog() over it. One logger and one file-sink handle per process, usable before the host is built (startup banner, warnings, pre-host Fatal), by SerilogAkkaLogger, and after the host is disposed (shutdown line, unexpected-termination Fatal) — AddZbSerilog's own DI registration would leave Log.Logger alone and have the host dispose the logger. LoggerConfigurationFactory is deleted (nothing else used it). Tests: existing logging/standby/sink tests now run through the new pipeline, plus ScadaBridgeLoggingParityTests (level precedence, Override:* still applies, one-shot warning, configured identity incl. NodeHostname != MachineName and empty SiteId, exact property set of a plain line, trace_id/span_id). Mutation-checked: governor deferring, filter removed, identity enricher removed, FromLogContext removed, capture sink removed each fail tests. Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
This commit is contained in:
@@ -52,9 +52,9 @@ public class SerilogSinkConfigTests
|
||||
Assert.Contains("File", sinkNames);
|
||||
}
|
||||
|
||||
/// <summary>Verifies that the logger configuration factory applies the configured file sink.</summary>
|
||||
/// <summary>Verifies that the host logger (shared AddZbSerilog bootstrap) applies the configured file sink.</summary>
|
||||
[Fact]
|
||||
public void LoggerConfigurationFactory_AppliesConfiguredFileSink()
|
||||
public void ScadaBridgeLogging_AppliesConfiguredFileSink()
|
||||
{
|
||||
// A `Serilog` section in configuration must actually reach the built logger
|
||||
// via ReadFrom.Configuration — proving the sink set is configuration-driven.
|
||||
@@ -72,9 +72,8 @@ public class SerilogSinkConfigTests
|
||||
})
|
||||
.Build();
|
||||
|
||||
var logger = LoggerConfigurationFactory
|
||||
.Build(configuration, "Central", "central", "node1")
|
||||
.CreateLogger();
|
||||
var logger = ScadaBridgeLogging.CreateLogger(
|
||||
configuration, "Central", "central", "node1", new StringWriter(), null);
|
||||
|
||||
logger.Information("host-014 configured-sink probe");
|
||||
logger.Dispose();
|
||||
|
||||
Reference in New Issue
Block a user